Well pumps · troubleshooting

Low water pressure on a well: a troubleshooting order

Weak showers on a well can come from a clogged filter cartridge or a pump that is wearing out, and guessing wrong gets expensive. Work from the cheapest, most common causes to the most expensive, and read a pressure gauge at each step so you know what changed.

As an Amazon Associate I earn from qualifying purchases. Product links below go to Amazon.

Bottom line Read the pressure gauge first. If pressure is low only at one fixture, it is that fixture. If it is low everywhere but the gauge reads normal, look at filters and treatment equipment. If the gauge itself reads low or keeps dropping, check the pressure switch and tank, then call a licensed well contractor about the pump and well.
Safety first Turn off the pump breaker before touching the pressure switch or draining the tank. The switch terminals carry line voltage. Pulling a submersible pump is a job for a licensed well contractor.

Step by step

  1. Is it one fixture or the whole house? Low flow at one faucet or shower is usually a clogged aerator or showerhead, not the well.
  2. Read the gauge while water runs. Open a tap and watch the gauge by the pressure tank. Note the cut-in (where the pump starts) and cut-out (where it stops). A common residential setting is 40/60, but check your switch. If the gauge is old or stuck, replace it — a 0–100 psi gauge with a 1/4″ NPT fitting is the usual size.
  3. Check filters and treatment. A clogged sediment cartridge, a fouled softener, or an iron filter that needs backwashing all drop pressure after the tank. If pressure is normal at the tank but low at the taps, put the system in bypass and see if it recovers. See Waterdrop whole-house filters for cartridge-based systems.
  4. Check the pressure switch. Pitted contacts or a clogged pressure-sensing port can make the pump stop early. See replacing a 40/60 pressure switch.
  5. Check the pressure tank. A waterlogged tank or wrong precharge causes pressure swings and rapid cycling. See pressure tank precharge and well pump short cycling.
  6. Look for leaks. A running toilet, a leak in the yard line, or a failing check valve can keep the system from building pressure.
  7. Then the pump and the well. If the pump runs and runs but cannot reach cut-out, the pump may be worn, the drop pipe may be leaking, or the well may not be keeping up (especially in dry weather or after heavy use). That needs a licensed well contractor to test.

What the gauge tells you

Gauge behaviorMost likely areaNext step
Normal at the tank, low at tapsFilters, softener, fixtures, or undersized pipingBypass treatment, change cartridges, clean aerators
Swings fast between cut-in and cut-outPressure tank precharge or waterlogged tankCheck precharge with the pump off and tank drained
Pump stops below the set cut-outPressure switch or its sensing portInspect or replace the switch (power off)
Pump runs long and never reaches cut-outPump wear, drop-pipe leak, or low well yieldCall a licensed well contractor
Pressure slowly drops with no taps openLeak or a failing check valveLook for leaks; contractor checks the check valve

Upgrading for steady pressure

If the pump is due for replacement or the house has outgrown a standard pressure-switch setup, a constant-pressure pump such as the Grundfos SQE keeps pressure steady as more taps open. See SQ vs SQE constant pressure and sizing a well pump by GPM and head. R.E. Merrill & Associates is a Grundfos dealer — ask us about SQ and SQE pumps for your well.

When to call a pro

Getting help

Start with a licensed well contractor for pump and well diagnosis and a licensed electrician for wiring. R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 and is a Grundfos dealer — contact R.E. Merrill & Associates about Grundfos SQ, SQE, and SP well pumps.