Sump pumps · how-to

How to size a sump pump: horsepower, flow, and head

Sump pumps are sold by horsepower, but horsepower does not tell you whether a pump will keep up in your basement. What matters is how many gallons the pump moves at the height and pipe run you have, compared with how fast water comes into your pit. This page is the sizing method. For a shortlist of pump types and features, see choosing a primary sump pump.

As an Amazon Associate I earn from qualifying purchases. Product links below go to Amazon.

Bottom line Work out total head (vertical lift plus friction in the pipe and fittings), measure your inflow during heavy water, then pick a pump whose published pump curve shows comfortably more flow than that inflow at your head. A licensed plumber or waterproofing pro can measure and confirm, especially for long runs or high lift.

1. Measure vertical lift

Measure from the pump (roughly the bottom of the pit) up to the highest point the discharge pipe reaches before it turns and runs out of the house. That vertical distance, in feet, is the static head. It is usually the biggest part of the load.

2. Add friction for the pipe and fittings

Water loses pressure as it moves through pipe, elbows, and the check valve. Longer horizontal runs, smaller pipe, more elbows, and higher flow all add friction. Pump makers and plumbing references publish friction-loss tables by pipe size and flow, and they treat each elbow and valve as an extra length of straight pipe. Add that friction loss to the vertical lift to get total dynamic head. If your run is short and simple, friction is a small add; if it is long or narrow, it can matter a lot. See sump discharge pipe sizing.

3. Measure how fast water comes in

The best data is your own pit during a heavy rain or snowmelt:

  1. Unplug the pump briefly (or let it shut off) and mark the water level.
  2. Time how long it takes the water to rise a known number of inches. Plug the pump back in before the water gets close to the top.
  3. Convert inches to gallons using the pit diameter. A round pit holds about diameter² × 0.0034 gallons per inch of depth (inches). That works out to roughly 1.1 gallons per inch for an 18-inch pit and about 2 gallons per inch for a 24-inch pit.
  4. Gallons divided by minutes gives inflow in gallons per minute; multiply by 60 for gallons per hour.

Measure on a bad day if you can; a dry-week measurement will undersize the pump. If you have never seen the pit under heavy inflow, ask a waterproofing pro what they see in similar homes nearby.

4. Read the pump curve

Every reputable pump publishes a performance curve or table: flow (GPM or GPH) at different heads, ending at a shutoff head where flow drops to zero. Find your total head on that chart and read the flow. That number, not the horsepower or the flow at zero feet, is what the pump will do in your basement.

CheckWhat you want
Flow at your total headClearly more than your measured peak inflow, with margin for heavier storms
Shutoff headWell above your total head, so you are not working at the very end of the curve
Discharge sizeMatches or steps up to your pipe size; see 1½″ vs 2″ discharge
Cycle lengthNot so oversized for a small pit that it short-cycles; see short cycling
Pump styleSubmersible or pedestal to fit the pit and use; see pedestal vs submersible

Common sizing mistakes

Getting help

Call a licensed plumber or waterproofing pro to measure lift and run, confirm inflow, and install the pump and discharge, and a licensed electrician for a dedicated circuit if needed. R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 — contact R.E. Merrill & Associates with pump sizing questions.

Related across the site

Sources