Water softeners · troubleshooting

Softener stuck in regeneration or running water to the drain

A softener normally sends water to the drain for a while during regeneration, often one to two hours depending on the valve and settings. If you hear water running at the drain long after that, or the display seems frozen in a cycle, the valve is either stuck or leaking internally. Either way it wastes water and salt, and it is worth sorting out quickly.

Bottom line First confirm it is really stuck: note the time, the cycle shown, and whether the flow ever stops. If it is, put the softener in bypass to stop the water loss, then work through power, motor, and seals. Call a licensed water-treatment pro when the valve needs to be opened up and you are not comfortable rebuilding it.

Normal regeneration vs a real problem

What you seeLikely meaning
Water to the drain for a set time at night, then quietNormal regeneration
Display stuck on one cycle (backwash, brine, rinse) for hoursMotor, gear, cam, or position-sensor problem
Steady trickle to the drain all day, even in serviceWorn piston seals, spacers, or a drain-side leak inside the valve
Long brine cycle and the brine tank level is not droppingPlugged injector or screen; see injector and screen cleaning
Brine tank overflowing or very fullFill or brine valve problem; see standing water in the brine tank
Regenerates every night when it should notSettings or meter issue; check hardness and capacity settings

What to check, in order

  1. Power. A tripped outlet, unplugged transformer, or power blip mid-cycle can leave the valve parked between positions. Restore power and see whether it finishes or returns to service.
  2. Clock and settings. Make sure the time of day is right and the regeneration time is set for when nobody is using water. A wrong clock can make a normal cycle look like a stuck one.
  3. Motor and drive. Many valves let you manually advance through the cycles. If the motor hums but the cycle does not advance, or the cam does not turn, the motor, gears, or position switch may need replacement.
  4. Seals and spacers. On piston valves such as the Fleck 5600SXT, worn seals and spacers commonly let water slip to the drain. A seal and spacer kit is the usual fix.
  5. Injector and screen. If the brine draw is blocked, the brine cycle can drag on with little salt pulled. Clean the injector and screen.
  6. Drain line. A kinked or partly blocked drain line, or a drain line without a proper air gap, can cause odd flow and code problems.

Stop the water loss safely

Parts

Getting help

Start with a licensed water-treatment pro for valve rebuilds, control board or motor replacement, and any drain or air-gap work that touches plumbing code. R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 — Contact R.E. Merrill & Associates.

Related across the site

Sources

More in this section