Fixtures · water supply
Supply lines and shutoff valves: braided lines and angle stops
The short hoses and little valves under sinks and behind toilets are some of the most common sources of sudden household leaks. Knowing the sizes and types makes replacement quick — and it means you can shut water off fast when something goes wrong.
Common supply line sizes
| Fixture | Valve end (typical) | Fixture end (typical) |
|---|---|---|
| Toilet | 3/8 inch compression | 7/8 inch ballcock (toilet) nut |
| Bathroom or kitchen faucet | 3/8 inch compression | 1/2 inch IPS/FIP or 3/8 inch compression, depending on the faucet |
| Dishwasher | 3/8 inch compression | 3/4 inch hose thread with an elbow, per the dishwasher manual |
| Ice maker or fridge | 1/4 inch compression | 1/4 inch compression |
Many faucets come with lines attached. Measure the run and buy a length that reaches without stretching or a tight kink — a gentle loop is fine.
Types of supply line
- Braided stainless: flexible, common, and widely available. Check the label for lead-free and potable-water listings.
- Plastic or vinyl: older and more likely to crack with age; worth replacing.
- Solid chrome or copper tubes: clean look, but must be cut and bent to fit.
- Leak-sensing or flood-stop lines: some lines and inline devices shut off on a burst; pair with leak sensors.
Supply lines do not last forever. Many manufacturers and insurers suggest replacing them on a schedule; check the maker’s guidance and inspect for rust, bulges, or kinks whenever you are under the sink.
Shutoff valves (stops)
| Choice | Options | Notes |
|---|---|---|
| Operation | Quarter-turn (ball) or multi-turn (compression stem) | Quarter-turn valves are easier to close fully and in an emergency |
| Shape | Angle stop (out of the wall) or straight stop (up from the floor) | Match where the pipe comes from |
| Inlet connection | Compression, sweat (solder), threaded, PEX crimp or expansion, push-to-connect | Must match pipe material and size — usually 1/2 inch nominal copper, PEX, or CPVC |
| Outlet | 3/8 inch compression is most common; 1/4 inch for ice makers | Dual-outlet stops can feed a faucet and dishwasher from one valve |
Replacing a supply line
- Close the stop and open the faucet or flush the toilet to relieve pressure.
- Unscrew both nuts; have the bucket ready.
- Thread the new line on by hand on both ends — do not use tape on compression fittings unless the maker says to.
- Snug with a wrench, typically a quarter to half turn past hand-tight; overtightening can crack the fixture nut.
- Open the stop slowly and check for drips now and again after an hour.
Replacing a stop valve
On copper with a compression stop, this is a manageable DIY job if the house shutoff works and the pipe is clean. Use a new ferrule if the old one is damaged or the pipe is too short. Sweat, soldered, and corroded galvanized connections are a plumber job.
When to call a pro
- Galvanized or corroded pipe behind the stop, or a stop soldered on — a licensed plumber.
- The main house shutoff does not close fully — a licensed plumber to replace it first.
- Water damage inside a cabinet or wall — a licensed plumber, and check with your insurer.
Start with a licensed plumber for anything that involves cutting pipe, opening a wall, or work your local code requires a permit for. R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 — contact R.E. Merrill & Associates.
Related across the site
- Softener bypass valves — the other valve to know in the utility room
- Tank tee kits — the well system’s main shutoff and drain
Sources
- NSF/ANSI 61 and 372 drinking-water component and lead-content standards.
- Supply line and stop valve manufacturer installation instructions.
- Model plumbing codes; check your local adopted code.