Sump pump won't turn on: a safe check order
A sump pump that sits silent while the pit fills is an emergency in slow motion. Most no-start problems are not a dead motor: they are lost power, a tripped GFCI or breaker, a float that is stuck or tangled, or debris jamming the impeller. Working through the checks in a safe order usually finds the cause quickly, and tells you when it is time to replace the pump or call a pro.
If water is about to overflow
- Run the battery backup or water-powered backup if you have one.
- Use a portable utility pump or a wet/dry vacuum to buy time. Keep cords and connections out of the water.
- If water is already on the floor near outlets, appliances, or the panel, stay out and shut power off at the main only if you can reach it from a dry spot. Otherwise call the utility or an electrician.
- For the bigger picture, see the basement flood-prep kit.
Safe check order
- Is the water high enough? Every switch has a turn-on level. A pump that does not start with only a few inches in the pit may be working normally. Note where the water is relative to the float.
- Check power at the outlet. Is the pump plugged in? On a piggyback float, the pump plugs into the back of the float plug, and both must be seated. Test the outlet with a lamp or plug-in tester rather than putting your hands in the pit.
- Check the GFCI and the breaker. Many basement outlets are GFCI protected, sometimes by a GFCI outlet in another spot on the same circuit. Reset it once. If it trips again, stop: see sump pump tripping the GFCI.
- Unplug, then free the float. With the pump unplugged, look for a tethered float pinned against the pit wall or liner, a cord tangled with the discharge pipe, or a vertical float rod that is binding or packed with debris. See sump float switches.
- Test the pump directly. On a piggyback setup, a common test is to unplug the pump from the float plug and plug it straight into the outlet briefly. If it runs, the float switch is the likely problem. If it does not, the pump is. Do this only from a dry spot and only for a few seconds if the pit is low.
- Hum but no spin. A hum without water moving usually means the impeller is jammed with gravel or debris, or the motor or its capacitor has failed. Unplug before clearing the intake screen. See how to clean a sump pit.
- Overheated motor. Many pumps have a thermal overload that shuts the motor off after long or hard runs and resets once it cools. Repeated shutdowns suggest a pump that is overworked or near the end of its life; see sump pump runs constantly.
- Runs but no water moves. That is a different problem, often a blocked or frozen discharge, a stuck check valve, or an air-locked pump. See sump check valves and sump discharge freeze protection.
Repair or replace?
A float switch is a common, inexpensive part to replace on many pumps. A pump that will not run when plugged directly into a live outlet, or that hums and will not clear once the intake is clean, is usually a replacement. Replacing with the same type, size, and discharge connection keeps the job simple. See how to replace a sump pump and choosing a primary sump pump.
Prevent the next no-start
- Test the pump on a schedule by filling the pit with water; see the sump pump test checklist.
- Add a high-water alarm or Wi-Fi monitor so you hear about a failed start before the floor gets wet; see sump alarms and Wi-Fi monitors.
- Consider a backup pump on its own float and power source.
Call a licensed electrician for repeated GFCI or breaker trips and wiring, and a licensed plumber or waterproofing pro for replacement and discharge work. R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 — contact R.E. Merrill & Associates with pump questions.
Related across the site
- Well pumps in a power outage — generator basics apply to sump pumps too
- Sump pump vs sewage ejector — make sure you are working on the right pump