Well pumps · controls

Well pump control boxes and start capacitors

If your well pump hums but will not start, trips the breaker, or quits after a storm, the problem may be in a gray box on the wall rather than down the well. Many 3-wire submersible pumps rely on a control box with a start capacitor and relay. Knowing what it is helps you describe the problem to a well contractor.

Bottom line A control box holds the starting parts for a 3-wire submersible pump. Failed capacitors and relays are common and cheaper than a new pump, but the box carries 230 volts and capacitors can hold a charge after power is off. Have a licensed well contractor or electrician test it. Never open it with power on.

Do you have a control box?

Pump typeControl box?Notes
3-wire submersible (plus ground)Yes, requiredBox holds start capacitor and relay or solid-state start switch
2-wire submersible (plus ground)NoStarting components are built into the motor; wiring runs from pressure switch to pump
Constant-pressure systems (e.g. Grundfos SQE)Uses its own controllerNot a standard capacitor box; see SQ vs SQE
Jet pumpsUsually noCapacitor is on the motor; see submersible vs jet pump

Count the wires going down the well at the pressure switch or wellhead, or check the label on the box. The control box must match the motor's horsepower, voltage, and brand; mismatched boxes can damage the motor.

What is inside

Symptoms that point to the control box

The same symptoms can come from a failed motor, a bad splice down the well, or a pressure switch problem, which is why testing matters. See well pump runs but no water and replacing a 40/60 pressure switch.

What a contractor typically checks

  1. Voltage at the pressure switch and control box.
  2. Capacitor values against the label, with the capacitor safely discharged.
  3. Relay or switch operation.
  4. Motor winding resistance and insulation resistance (megger) from the box, which can tell a bad box from a bad motor or cable before anyone pulls the pump.
  5. Amp draw while running, compared with the motor nameplate.

Safety notes

Tools and references

Getting help

Start with a licensed well contractor to test the control box, motor, and wiring before replacing anything. If the pump itself needs replacing, R.E. Merrill & Associates can help with Grundfos residential well pumps, including constant-pressure SQE systems that do not use a separate capacitor box. R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 — Contact R.E. Merrill & Associates.