Well pumps · how-to

How to prime a jet pump after it loses prime

A jet pump sits above ground and has to lift water up to itself, so its pump body and suction line must be full of water to work. If air gets in — after a power outage, a drained system, a repair, or a slow suction leak — the pump can run without moving water. Priming refills the pump and suction pipe so it can pull again. Running a jet pump dry even briefly can damage the seal and impeller, so the order of steps matters.

As an Amazon Associate I earn from qualifying purchases. Product links below go to Amazon.

Bottom line Power off at the breaker, fill the pump through the priming port until no more air comes out, reinstall the plug, then restore power and watch the gauge climb. Repeat a few times if needed. If it will not hold prime, look for a leaking foot valve or check valve, an air leak on the suction side, or a well that is drawing down. A licensed well contractor should handle anything in the well itself. Not sure you have a jet pump? See submersible vs jet pump — submersible pumps do not need priming.

Signs a jet pump has lost prime

If the pump hums but does not spin, or trips the breaker, that is an electrical problem, not prime. Stop and see well pump runs but no water.

Before you start

Priming steps (typical shallow-well jet pump)

  1. With power off, remove the priming plug on top of the pump body (some pumps have a priming tee on the suction side).
  2. Pour clean water in slowly until the pump body and suction line are full and water stands at the top of the port with no more bubbles. This can take more water than you expect on a long suction line.
  3. Wrap the plug threads with fresh thread sealant tape and reinstall it snugly.
  4. Restore power. Watch the pressure gauge: it should start to climb within a minute or two.
  5. If pressure does not build after a short run (follow your manual’s time limit), turn the power off, let it cool, and repeat the fill. It often takes two or three cycles to purge all the air.
  6. Once it builds pressure and shuts off at cut-out, open a faucet and let it cycle a few times to clear remaining air.

Convertible or deep-well jet pumps have a drive pipe and a suction pipe going to an ejector in the well, and some have a pressure control valve. Priming them usually means filling both pipes and setting the control valve per the manual. If you are not sure which you have, call a contractor rather than guessing.

Why a jet pump keeps losing prime

CauseCluesWho fixes it
Leaking foot valve or check valvePressure drops overnight with no use; pump must be re-primed oftenWell contractor (foot valves are down the well); see check valves
Air leak on the suction sideBubbles in the water, loss of prime without a pressure drop at rest; cracked fittings, loose unions, failing pipePlumber or well contractor; suction leaks pull air in rather than drip water out
Water level dropping below what the pump can liftWorks at first, loses prime during long use or dry weatherWell contractor; see is my well running dry?
Clogged foot valve screen or intakeWeak flow, cavitation noise, then lost primeWell contractor
Worn impeller, jet, or ejectorHolds prime but cannot reach cut-out pressurePump service or replacement

A shallow-well jet pump can only lift water a limited distance by suction (the pump’s literature lists it, and practical lift drops with altitude). If the static or pumping level is near that limit, it will keep losing prime no matter how carefully you fill it.

When a submersible is the better long-term answer

If the well is deep, the water level falls in summer, or the suction line is long and leak-prone, a properly sized submersible pump can remove the priming problem entirely because it pushes water up instead of pulling it. That is a sizing decision for a well contractor or pump dealer; see sizing a well pump by GPM and head and residential well pump basics.

Parts and references

We do not link pumps on this page. Pump selection depends on well depth, water level, and household demand; get it sized by a well contractor or a Grundfos dealer.

Getting help

Start with a licensed well contractor (and a licensed electrician for wiring) if the pump will not hold prime, the foot valve needs replacing, or the water level may be the problem. If you are ready to replace a jet pump or move to a submersible, R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 and can help with Grundfos residential well pumps — contact R.E. Merrill & Associates.

Related across the site

Sources

More in this section