Well pumps · troubleshooting
Well pump won't shut off: what to check first
On a standard pressure-switch well system, the pump starts at the cut-in pressure and stops at the cut-out pressure (for example 40 and 60 psi on a 40/60 switch). If the pump runs and runs, either something is still using water, the pump cannot reach cut-out pressure, or the switch is not telling it to stop. A pump that never shuts off can overheat, run dry, or overpressure the system, so it is worth working through the checks quickly and safely.
Read the gauge first
| What the gauge shows | Likely meaning | First move |
|---|---|---|
| Pressure rises past cut-out and keeps going | Pressure switch contacts stuck closed, or a clogged sensing port that does not see the pressure | Shut off the pump breaker; call a well contractor |
| Pressure sits steady a few psi below cut-out | Pump is close but cannot quite reach the setting: worn pump, low water level, or a switch set too high for the pump | Check demand and leaks, then call a contractor |
| Pressure low or dropping while the pump runs | Heavy demand, a leak, a split drop pipe, or the well is drawing down | Shut off water use; see pump runs but no water |
| Gauge needle does not move at all | Gauge may be broken or its port clogged | Verify with a second gauge — see well pressure gauges |
| Pump starts and stops rapidly rather than running nonstop | A different problem: short cycling | Well pump short cycling |
Constant-pressure systems (such as a Grundfos SQE with a controller) are designed to run longer at variable speed while water is in use. Long run times during demand are normal there; continuous running with every tap closed is not. See SQ vs SQE constant pressure.
Safe check order
- Close every tap and check for demand. Look for a running toilet, an irrigation zone, a softener or filter stuck in backwash, an outdoor hose, or a livestock waterer. See toilet fill valve and flapper fixes and softener water running to the drain.
- Look for a leak. With all water off, watch the gauge after the pump stops (or turn off the breaker once pressure is up). If pressure keeps falling, water is going somewhere: a leak in the house, the buried line from the well, or back down the well through a bad check valve. Wet spots in the yard between the well and the house are a clue.
- Check whether pressure is climbing past cut-out. If it is, turn off the pump breaker. Do not keep resetting it. Most systems have a pressure relief valve, but do not rely on it.
- Suspect the pressure switch. Burned or welded contacts can stick closed. The small tube or nipple under the switch can also clog with sediment or iron so the switch never sees the real pressure. Both are common, inexpensive fixes, but the switch has line voltage; turn off the breaker and verify power is off before opening the cover, or have an electrician or well contractor do it. See replacing a 40/60 pressure switch.
- Consider the pump and the well. A worn pump, a hole in the drop pipe, a stuck or leaking check valve, or a water level that has dropped can leave a pump running without reaching cut-out. These need a contractor with test equipment. See is my well running dry? and check valves and torque arrestors.
- Check the switch setting. If someone raised the cut-out pressure (for example from 40/60 to 50/70) and the pump was never sized for it, the pump may struggle to reach it. Settings should match the pump curve and the tank precharge; see pressure tank precharge.
Why not just let it run?
- Overheating and wear: a pump that never stops runs hot, especially if flow is low.
- Dry running: if the well is drawing down, the pump can run out of water and be damaged. Some pumps and controls have dry-run protection; many older systems do not.
- Overpressure: a stuck switch can push pressure past what pipes, fittings, and the tank are rated for.
- Electric bills: continuous running adds up quickly.
Tools and references
- Well pump pressure switches (Amazon search, high to low) — match the range to your system; installed by a qualified person with power off
- 0–100 psi water pressure gauges (Amazon search, high to low) — a known-good gauge to confirm what the switch is seeing
- Well check valves (Amazon search, high to low) — for contractor-installed replacements; match pipe size and material
- Books on water wells (Amazon search, high to low) — see also books for private well owners
We do not link pumps on this page. Pump selection depends on well depth, yield, and pressure needs; get it sized by a well contractor or a Grundfos dealer.
Start with a licensed well contractor (and a licensed electrician for wiring) to test the switch, check valve, pump amperage, and water level before replacing anything. If the pump itself needs replacing, R.E. Merrill & Associates has handled industrial and municipal pumps and fluid systems since 1987 and can help with Grundfos residential well pumps — contact R.E. Merrill & Associates.
Related across the site
- Low water pressure on a well
- Well pump control boxes and start capacitors
- Leak sensors for the basement and well tank
Sources
- Pressure switch and pressure tank manufacturer installation and troubleshooting instructions.
- Grundfos residential pump literature (SQ, SQE, and constant-pressure controls).